FLUKE Digital Multimeter, FLUKE 17B+. 2 AA, NEDA 15 A, IEC LR6. AC Current: Range: 4.000 A to 10.00 A, Resolution: 0.001 A to 0.01 A, Accuracy: 1.5 % + 3 DC Current: Range: 4.000 A to 10.00 A, Resolution: 0.001 A to 0.01 A, Accuracy: 1.5 % + 3. 183 mm x 91 mm x 49.5 mm.
Range: 4 V to 1000 V Resolution: 0.001 V to 1 V Accuracy: 0.5 % + 3. Range: 400.0 to 40.00 M Resolution: 0.1 Accuracy: : 0.5 %+3 to 1.5 % + 3. CAT III 600 V, CAT II 1000 V. 30 °C to 60 °C.Temperature coefficient: 0.1 X (specified accuracy) /°C. Range: 50°C to 400°C, 0°C to 50°C, -55°C to 0°C Resolution: 0.1°C Accuracy: 2 % -1°C, ±2°C, 9 % ± 2°C.
Cases and Holders: Fluke TPAK ToolPakTM Magnetic Meter Hanger Kit includes: 9 inch hook and loop strap, Universal hanger clip, Hook hanger for non magnetic surfaces. Test Leads: TL75 TwistGuard Test Leads. Range: 40.00 nF to 1000 F Resolution: 0.01 nF to 1 nF Accuracy: 2 % + 5 to 5 % + 5. Range: 50.00 Hz to 100.0 kHz Resolution: 0.01 Hz to 0.1 kHz Accuracy: 0.1 % + 3. Relative humidity: Operating humidity: 90 % RH at 10 °C to 30 °C; 75 % RH at 30 °C to 40 °C; non-condensing.
The Fluke 17B+ digital multimeters are compact, easy to use tools that deliver safe, reliable measurement All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. Typically, open circuit test voltage is 2.0 V and short circuit current is. 80 % RH at 10 °C to 30 °C; 70 % RH at 30 °C to 40 °C.
Specifications AC Milli Volts: Range: 400.0 mV, Resolution: 0.1 mV, Accuracy: 3.0 % + 3 DC Milli Volts: 400.0 mV, Resolution: 0.1 mV, Accuracy: 1.0 % + 10 Diode Test: Range: 2 V, Resolution: 0.001 V, Accuracy: 10% Diode Cycle: Range: 1 % to 99 %, Resolution: 0.1% Function AC volts: Overload Protection: 1000 V', Input Impedance: >10 M. 60 dB at dc, 50 Hz or 60 Hz AC Mini Volts: Overload Protection: 400 mV, Input Impedance: >10 M. >80 dB at 50 Hz or 60 Hz DC volts: Overload Protection: 1000 V', Input Impedance: >10 M.
100 dB at dc, 50 Hz or 60 Hz, Normal Mode Rejection Ratio: >60 dB at 50 Hz or 60 Hz DC Mini Volts: Overload Protection: 400 mV, Input Impedance: >10 M. >80 dB at 50 Hz or 60 Hz. Altitude: Operating: 2000 m; Storage: 12,000 m. Fuse protection for current inputs: 440 mA, 1000 V fast fuse, Fluke specified part only. 11 A, 1000 V fast fuse, Fluke specified part only Electromagnetic environment: IEC 61326-1: Portable.
The item "FLUKE F17B+ Digital Multimeter Meter Tester wth LCD Display Temperature, CAT III" is in sale since Thursday, February 15, 2018. This item is in the category "Business, Office & Industrial\Test, Measurement & Inspection\Test Meters & Detectors\Multimeters". The seller is "wholesale_shop1" and is located in Crawley, West Sussex. This item can be shipped worldwide.